VOLT POWER SINUS UPS 2000 24V | Power supply | 2000W

The POWER SINUS series uninterruptible power supply is equipped with many innovative solutions, while being the most popular brand of affordable uninterruptible power supplies on the market. The device is a combination of an inverter, a universal mains rectifier, and an automatic mains switch (AC) in one circuit with a peak DC/AC conversion efficiency of approximately 88%. Power Sinus UPS 2000 24V offers multi-stage charging with power factor correction and a "pure" sinusoidal signal at an output with an unprecedentedly high pulse power to meet the high demands of emergency power equipment.
The Power Sinus UPS 2000 is characterized by a high instantaneous power (overload), it oscillates at a level of about 300% of the nominal power, which is maintained to about 20s, so that the device allows for economical operation with advanced electrical equipment. The power consumption at standstill reaches up to 4% of the nominal power. The use of the SC PRIORITY/BATTERY PRIORITY priority switch and automatic start of the generator makes the device perfect for operation in both emergency power supply systems or for renewable energy applications.
The PSU has been equipped with LED and buzzer sound lights, which inform about the status of the device and facilitate operation and search for possible problems. Additionally, the PSU can be equipped with an external control panel, which is equipped with a display presenting the most important device parameters.
VOLT POWER SINUS UPS 2000 24V is ideal for supplying electrical equipment that requires 230V AC from a 24V DC battery. Additionally, the power supply can be used as an emergency power source for devices requiring continuous power supply.
Features / filters | |
Battery voltage in UPS | 24V |
UPS power (VA) | 2000 |
Voltage (V) / Power (W) | 24V / 2000W |
Inverter output parameters: | |
Continuous power | 2000 W |
Instantaneous power | 6000 VA |
Output voltage | Pure sinus |
Inverter efficiency | 88% |
Efficiency in network mode | >95% |
PFC | 0.9-1.0 |
RMS output voltage | 230 VAC |
Output voltage adjustment | ±10% RMS |
Output frequency | 50 ± 0.3Hz |
Short circuit protection | Yes, with current limiter function after 1s |
Typical transfer time network / sound | 10ms (max) |
THD | < 10% |
Input parameters of the inverter: | |
Input voltage | 12 VDC or 24 VDC |
Minimum input voltage | 10.0VDC |
Low voltage signalling | 10.5VDC / 11.0VDC |
Under-voltage cut-off | 10.0VDC / 10.5VDC |
Overvoltage signalling and cut-off | 16.0VDC |
Maximum input voltage | 15.5VDC |
Sleep mode threshold | > 25 W in Power Saver On mode |
Input voltage range | Narrow: 194~243VAC Wide: 164~243VAC |
Input frequency range | Narrow: 47-55±0.3Hz for 50Hz Wide:43±0.3Hz plus for 50Hz |
Rectifier | |
Output voltage | Depending on battery type |
Max. charging current 12 VDC | 65 +/- 5A |
Max. charging current 24 VDC | 30 +/- 5A |
Before you overload. | 15.7V for 12VDC ( *2 for 24VDC) |
Battery types | Fast VDC |
Gel U.S.A. | 14V |
A.G.M. 1 | 14,1V |
A.G.M 2 | 14,6V |
Sealed Lead Acid | 14,4V |
Gel Euro | 14,4V |
Open Lead Acid | 14,8V |
Calcium | 15,1V |
De-sulphation | 15.5V for 4 hours |
Remote control | Yes (option) |
Bypass and safeguards | |
Input voltage | sinusoidal (network or generator) |
Nominal voltage | 230VAC |
Under-voltage cut-off | 184V/154V±4% |
Under-voltage excitation | 194V/164V±4% |
Overvoltage cut-off | 253V±4% |
Overvoltage excitation | 243V±4% |
Input frequency | 50Hz |
Short-circuit protection for outputs. | Automatic fuse |
Fuse (230VAC) | 20A |
General data | |
Fixing | Mounting to the wall or lying down |
Dimensions (Length*Ser*Wys) | 442*218*179mm |
Net weight | 20KG |
Gross weight (including packaging) | 22KG |
Packaging (Length*Ser*Wys) | 530*325*3 15mm |
Pure Sinus
Yes, the device works with solar panels (no solar regulator)