Orvaldi V1100+ Sinus 2U LCD | UPS | 1100VA/990W, 2x 9Ah
CODE: VOT1100+ / EAN: 5904006036856

EN
Uninterruptible power supplies of the UPS type provide short-term operation of home or office equipment in the event of a power cut in the general network. Operating in normal mode, UPSs, thanks to their built-in AVR, act as a voltage stabilizer. The voltage range of the mains supply is 162 to 290V. ORVALDI V(L) 1.1kVA to 3KVA with a power factor of 0.9, provides servers with full power protection from power failures as well as from the effects of power surges and peaks.
With the added advantage of a universal Rack / Tower chassis and an easy-to-read and user-friendly LCD, the Orvaldi V1100 Sinus 2U LCD is ideal for networking, telecommunications, servers and critical applications.
Features / filters | |
Battery voltage in UPS | 12V |
UPS power (VA) | 1100 |
AC outlet types | IEC 320 |
AC outlets quantity | 8 |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
Audible alarm(s) | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Battery capacity | 9 |
Battery voltage | 12 |
Cold start | Yes |
Crest factor | 3:1 |
Depth | 410 |
Display type | LCD |
ECO mode | Yes |
Efficiency | 89 |
Efficiency (ECO mode) | 97 |
Emergency Power Off (EPO) | Yes |
Form factor | Rackmount/Tower |
Height | 88 |
Input frequency | 50/60 |
Input operation voltage (max) | 290 |
Input operation voltage (min) | 162 |
LED indicators | Yes |
Noise level | 55 |
Number of batteries supported | 2 |
Operating relative humidity (H-H) | 0 - 90 |
Operating temperature (T-T) | 0 - 40 |
Output frequency | 50/60 |
Output operation voltage (max) | 240 |
Output operation voltage (min) | 220 |
Output power | 990 |
Output power capacity | 1.1 |
Output voltage regulation | 25 |
Output voltage Total Harmonic Distortion (THD) | 10 |
Power factor | 0.9 |
Power protection features | Overcharge, Overdischarge, Overload |
Product colour | Black |
Rack capacity | 2U |
Response time | 10 |
Serial interface | Yes |
Serial interface type | RS-232 |
Serial ports quantity | 1 |
UPS topology | Line-Interactive |
USB port | Yes |
Waveform | Sine |
Weight | 13.4 |
Width | 438 |
Technical data | |
Model | ORVALDI V1100 sinus 2U LCD |
Power | 1100 VA / 990 W |
Voltage | 208/220/230/240 VAC |
Adm. input voltage | 162-290 VAC |
Adm. frequency range | 50 Hz |
Voltage Selection (AC Mode) | 208/220/230/240 VAC |
Stabilization (Batt. Mode) | ± 3% (before battery alarm) |
Frequency (Batt. Mode) | 50 Hz ± 1 Hz |
Current Crest Ratio | 3:1 |
Harmonic distortion | 8% max @ 100% linear load, 15% max @ 100% non-linear load (before alarm) |
Voltage shape (Batt. Mode) | Pure sine wave |
Switchover time | Typically 2-6 ms, 10ms max |
AC Mode | 97% |
Buck | 90% |
Battery Mode | 83% |
Type and quantity | 12 V/9 Ah x 2 |
Charge voltage. | 27.4 VDC ± 1% |
Typical charging time | 4 hours to 90% capacity |
Full security | Against overloading, discharging, overcharging |
Option - SNMP card | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC |
RS-232/USB communication | Power management from SNMP manager and web browser |
LCD panel | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery. |
Battery Mode | Signal every 10 sec. |
Low Battery | Signal every second |
Overload | Signal every 0.5 seconds |
Fault | Continuous signal |
Dimensions ( D x S x W ) | 410 x 438 x 88 |
Weight | 14.23 |
Moisture | 0-90 % RH @ 0- 40°C (non-condensing) |
Noise level below | 45dB |