EN

GREEN CELL UPS | UPS | Micropower, 1500VA

CODE: UPS04 / EAN: 5902701419646

GREEN CELL UPS | UPS | Micropower, 1500VA

CODE: UPS04 / EAN: 5902701419646
117,47 GBP without VAT (net)
Out of stock
UPS power (VA): 1500
AC outlets quantity: 5
Battery capacity: 9
Battery recharge time: 8
Show more parameters
UPS power (VA):

About product

Green Cell 1500VA 900W Power Proof UPS

The Green Cell  Power Proof UPS with a nominal power rating of 900W is an offline line-interactive model - this means that it is equipped with a fully automatic voltage regulator, which has a primary function as a voltage dropout protection, it also has ró protection against mains interference. The ró allows the device to switch to battery power at a level of 2-6 ms in an instant, thus protecting our work and unsaved files from loss. AGM Green Cell batteries with a life of more than 5 years. The back-up time depends mainly on the power of the connected device and the appropriately selected UPS model, so it is worth remembering that when choosing a UPS, the power of the connected devices does not exceed 80% of its nominal value.

.

Green Cell 1500VA 900W Power Proof UPS

Application of the Green Cell 1500VA 900W Power Proof UPS

Due to its simple design, relatively low price and the use of a modified sine wave, the device is ideal as a protection of sensitive devices against damage caused by fluctuations in the mains or in case when the mains power failure makes it impossible to record the effects of our work. It is often used to power both cash registers and alarm systems, i.e. devices that provide safety and possibility to continue work. It is one of the most popular models used for office computers, treated as a protection against sudden voltage loss, which can cause the computer to shut down. Thanks to the Green Cell emergency power supply, you will avoid the situation in which it will be impossible to save your work on your computer. It is important to note that the UPS not only provides backup power in the event of a power outage, but also guarantees safety for often expensive electronics against voltage fluctuations.

UPS Micropower 1500VA Green Cell UPS

Specification

Features / filters
UPS power (VA) 1500
AC outlets quantity 5
Battery capacity 9
Battery recharge time 8
Battery voltage 12
Depth 158
Form factor Tower
Height 198
Input frequency 50/60
Input operation voltage (max) 240
Input operation voltage (min) 220
Output frequency 50/60
Output operation voltage (max) 230
Output operation voltage (min) 230
Output power 900
Output power capacity 1.999
Power protection features Over voltage, Short circuit
Product colour Black
Response time 2
UPS topology Line-Interactive
USB port Yes
Waveform Sine
Weight 11.1
Width 380

Technical parameters
Apparent power 1500VA
Power 900W
Safeguards thermal, surge protection, short circuit protection
Product code UPS04
Weight 11.1kg
Manufacturer Green Cell
Guarantee 24 months (12 months per battery)
Communication USB/RJ45
Indicator LCD
Input voltage 220/230/240 V
Input frequency 50/60 Hz
Output voltage 230 V
Output voltage shape Modified sinusoidal
Output frequency 50Hz or 60Hz (automatic detection)
Nests 4x Schuko + IEC
Typical charging time 6-8 hours
Response time 2-6 ms
Type of housing Tower
Battery 2 x 12V/9Ah
Topology Line-Interactive
Dimensions 380 x 158 x 198 mm

Support

Downloads
Operating instructions Download
Firmware Download

Faq

Why is it important to have a UPS?

Lack of stability of the power grid may have a negative impact on the operation of, among others, computers. In addition to an additional power source, the UPS guarantees stability and deprives the power source of interference. This is due to current regulation and filtration, while protecting the equipment from damage caused by lightning.

UPS and laser printers

Laser printers are characterized by a power surge when switched on and during printing. Therefore, it is important to choose the correct power supply. Most often it oscillates within a few kVa.

How to match the power of the power supply to the protected computer hardware?

In order to correctly select the power of the UPS, the power of all the loads that we would like to protect should be added together. An important parameter of apparent power, expressed in VA. The values are given on the equipment nameplates, otherwise multiply the voltage [V] and current [A].

Devices often have the power given in Watts [W]. To obtain the value in VA, the total power of the devices in Watts should be multiplied by a factor of 1.4. It should be remembered that the power of the PSU is about 20-30% higher than the total power of the protected devices.

117,47 GBP without VAT (net)
Out of stock
Print version
Session will expire in:
Seconds
You will be logged out after the session expires
Choose a different country or region to shop in the language that suits you
Our site uses cookies (so-called "cookies"). You can find more about these files, as well as about how we process your personal data, in our privacy policy.
You are on page for country / region:
English (EN)
Please select a different country or region to shop in a language that suits you.